Customization: | Available |
---|---|
Industrial Use: | Pharmaceutical, Pdlc Smart Dimming Film |
Thickness: | 2mm-5mm |
Still deciding? Get samples of US$ 26/Square Meter
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Performance | ||||
Smart PDLC Film Test Result / Description | Status | Data | Remarks | |
Optics |
Parallel light transmittance | on | > 83% | GB/T 2410-2008 |
off | < 4% | |||
Visible light transmittance | on | >80% | GB/T 22476-1994 | |
off | > 50% | |||
SHGC | off | 51% | / | |
on | 82.9% | / | ||
SC |
off | 0.59 | / | |
on | 0.95 | / | ||
U Value | on/off | 5.59W/m2•k | GB/T 22476-2008 | |
Haze | on | < 6% | GB/T 2410-2008 |
|
off | > 90% | |||
UV Block | on/off | > 98% | / | |
viewing angle | on | > 160∘ | / | |
Electrical |
Power voltage | on | 60VAC | electrical measuring instrument |
Response time | on → off | < 200ms | Liquid crystal measuring instrument | |
off → on | < 45ms | |||
Power consumption | on | < 5W/ M 2 | multimeter | |
Environment |
Work Temperature | on/off | - 20ºC to + 70ºC | Far from heat, chemical, liquid, wet. |
Storage Temperature | / | - 15ºC to + 50ºC | ||
Humidity | / | < 70%RH | ||
Duribility |
Life time | / | > 50000 Hours | / |
Switch time | / | > 5 million | / | |
peel strength | / | > 70 gf/inch | / | |
Temperature - 20ºC, +70ºC, Humidity > 95%RH 240 H test passed | ||||
PDLC Film | Thickness | Standard Size | Length tolerance | Width tolerance |
Roll | 390µm ± 10% | 1.0*50m, 1.2*50m,1.5*50m, 1.8*50m, 2.0*50m | +0. 5 / -0 meter | +5 / -0 mm |
Sheet with busbar | 390µm ± 10% | Max. 2.0 *4.8 M | +0 / -2 mm | +0 / -2 mm |
Item | Performance / Unit | Testing Method and Standard | |
Rated Voltage | ON | 36/48/60(AC50HZ) | Multimeter |
Power Consumption | ON | 4-6w/(SQM) | Multi-parameter Electrical Measuring Instruments |
Total Light Transmittance | ON | >83% | GB/T 2410-2008GB/Spectrophotometer |
OFF | >67% | ||
Directional Light Transmittance | ON | >80% | GB5137.2-2002 |
OFF | <4% | ||
Haze | ON | <4% | GB/T 2410-2008GB/Spectrophotomete |
OFF | >96% | ||
Response Time | ON | <40(MS) | Liquid Cystal Mutl-prareter. Measuring Instrument |
OFF | <210(MS) | ||
Operating Temperature | / | -30~70ºC | Constant Temperature and Humidly Testing Machine |
Lifetime | ON | >100000(H) | GB18910.5- 2008 |